LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1249

Lignum ID-№
D1249
Catalog number
D.1.02.awrhhi14a-00
Source of construction assembly
Fundermax / Dataholz, Year 2024
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Substructure rigid screwed
Construction height
314 mm
Weight
67 kg/m2
U-value
≈ 0.193 W/m2K
GWP
35.50 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering with cavity insulation. Ventilated facade.
Values of airborne sound insulation
Rw 43 dB
C -1 dB
Ctr -6 dB

Comment Der Einsatz der geeigneten Dampfbremse und der Fassadenbahn ist Projektbezogen zu klären.

Graphic

Cover leftside 1st layer: Grooved comb paneling, VSH profile no. 41a
Battens / profiles (ventilation): crossed laths 2x 30x50mm
Coupling: Façade membrane with sd ≤ 0.3 m with EPDM sealing tape 1.2 mm for ventilation cavity
Sheathed outside leftside 1st layer: Medium-density fibreboard MDF 600 kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: Biofaser HB.HLA 2 Funderplan
Battens / profiles: Wood lath b=75mm
Cavity dampening: Wood fiber board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Grooved comb paneling, VSH profile no. 41a VSH 19 mm 9.3 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) crossed laths 2x 30x50mm Generic product, Label swiss wood 60 mm 2.4 kg/m2 50 mm 625 mm 07.011 91.052
Coupling Façade membrane with sd ≤ 0.3 m with EPDM sealing tape 1.2 mm for ventilation cavity Generic product 0.2 mm 0.1 kg/m2 - - 09.008 91.037
Sheathed outside leftside 1st layer Medium-density fibreboard MDF 600 kg/m³ Generic product 15 mm 9 kg/m2 - - 07.012 91.050
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood, Schilliger Holz 160 mm 7.5 kg/m2 60 mm 625 mm 07.003.01 91.047
Cavity dampening Cellulose: Loose; not monitored Generic product 160 mm 8 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Biofaser HB.HLA 2 Funderplan Fundermax 8 mm 8 kg/m2 - - 07.004 91.049
Battens / profiles Wood lath b=75mm Generic product, Label swiss wood 40 mm 2.4 kg/m2 75 mm 625 mm 07.011 91.052
Cavity dampening Wood fiber board ≥ 180kg/m³ Gutex, Isover 40 mm 7.2 kg/m2 - - 10.009 91.051
Covering rightside1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 12.5 mm 13.3 kg/m2 - - 03.007 91.063
Surface rightside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 10 12 14 16 16 16 22 27 35 42 48 55 61 67 73 79 84 90 96 102 110 110

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
63500
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
56554
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6950
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
446.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
439.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
199.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
240.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
291.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
291.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
68.80
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
222.10
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.50
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
154.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
148.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
130.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
17.70
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.80
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
35.50
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.70
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.80
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
83.60
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
22.80
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)